SUNOPEN A24PA V1.3: MPPT Controller With Integrated ATS

SUNOPEN A24PA V1.3: MPPT Controller With Integrated ATS

Most off-grid solar systems do not fail because the array is too small. They fail on the third cloudy day, when the battery has already given everything it had and the load still needs power.

The SUNOPEN A24PA V1.3 is built for that exact failure mode. It packs a 300 W MPPT tracker and a complete automatic transfer switch (ATS) into a single 97 × 170 × 37 mm case, so the controller can top the battery up from a mains DC supply when solar simply is not delivering.

1. Why an off-grid site needs a second source

A well-sized off-grid system is designed around average daily yield, not the worst week of the year. That is a rational trade-off: oversizing the array and the battery bank to survive a two-week monsoon can double the cost of every installation.

A supplementary DC input changes that economics. You size the array for normal conditions and let the controller borrow from the grid — or from a DC bus, generator rectifier or another DC source — only when the battery crosses a threshold you define.

2. What "integrated ATS" actually means on the A24PA

ATS stands for automatic transfer switch: the unit decides which source charges the battery, and switches without manual intervention. On the A24PA the switching hardware reuses the controller's own DC/DC converter — the same power stage that runs MPPT — which is why the enclosure stays this small and the cost stays low.

Four settings define the behaviour in the field:

  • Aux start / stop voltage — the battery voltage at which mains DC charging begins and ends.
  • Low-light statistics — the controller measures harvested energy over a window; if the total stays below your threshold, DC charging is forced.
  • Forced aux time — how long the forced DC stage may run before the controller re-evaluates.
  • Priority mode — PV first or Aux first, selectable in the settings menu.

Aux charging power is on par with the controller's own MPPT charging: up to 300 W at 24 V and 180 W at 12 V, with conversion efficiency above 96%.

3. A24PA V1.3 key specifications

ParameterValue
Battery platform12V / 24V — LiFePO4 3–8S, NMC 3–7S, lead-acid 1–2S
System modeBuck (step-down)
Rated charge current14.5 A
Max PV input current12 A
Max solar panel power300 W
PV open-circuit voltage<56 V (63 V system withstand)
Recommended PV Vmp18–50 V
AUX (mains DC) input<52 V, 12 A, 180 W at 12 V / 300 W at 24 V
MPPT tracking efficiency>99.9%, <1 ms
Charge conversion efficiency>96%
Rated load current12 A — Auto / Remote / Intermittent / Street light
Dimensions / weight97 × 170 × 37 mm / 0.5 kg
Protection / temperatureIP32, −35 °C to 65 °C, natural + forced cooling
CommunicationRS485 and TTL (Modbus), Bluetooth / Ethernet optional

4. A winter example

Take a 24 V, 100 Ah LiFePO4 bank feeding a 60 W camera pole. A 300 W array yields roughly 1.0–1.2 kWh on a clear day, but only 0.2–0.3 kWh under heavy cloud. Two consecutive grey days put the bank near 50%.

With ATS enabled and the start threshold at 24.5 V, the controller switches to the DC input, holds charging until the stop threshold (say 27 V), then hands control back to PV. The site keeps running without a site visit — and the array is never oversized for weather it sees twice a year.

5. Charging profile and battery support

Charging follows a four-stage curve: activation (pulse) for deeply discharged packs, trickle, constant current, constant voltage — then a full-charge cutoff with automatic recharge hysteresis.

Battery type and series count are configurable — LiFePO4 3–8S, NMC 3–7S, lead-acid or gel 1–2S, or a custom 10–30 V window. An optional NTC sensor (B3950 10 kΩ) adds temperature compensation and over-temperature charge cut-off.

6. Where the A24PA fits best

  • Solar CCTV and PTZ poles — sites that must stay online through a rainy week.
  • Street lighting and traffic signs — where a dark week is a safety issue, not an inconvenience.
  • Telecom and IoT gateways — remote cabinets with a DC bus already present.
  • Monsoon and winter markets — regions with a predictable low-yield season.
  • RV and marine shore power — top-up charging while moored or parked.

7. Commissioning checklist

  1. Connect the battery first, then PV, then the aux DC source — never the other way round.
  2. Set battery type and series count before switching on the load.
  3. Confirm aux start/stop voltages against the battery datasheet.
  4. Size the aux breaker for the 12 A input rating, and fuse the PV side separately.
  5. Earth the enclosure and verify PV Voc stays below 56 V at the coldest expected temperature.

8. FAQ

QuestionAnswer
Does the A24PA replace the PV array?No. ATS is insurance for low-yield periods; the array still does the daily work. Size PV for average conditions and let ATS cover the gaps.
Can one unit charge both 12 V and 24 V banks?Yes. The V1.3 hardware covers a 12V/24V platform, with LiFePO4 support from 3 to 8 series cells.
What is the maximum PV input?300 W of panel, 12 A of input current, and an open-circuit voltage below 56 V (63 V absolute withstand).
Is aux charging as powerful as solar charging?The aux input is rated 300 W at 24 V and 180 W at 12 V, close to the 300 W PV ceiling, so a full top-up takes hours rather than days.
Can I monitor the site remotely?RS485 and TTL Modbus are standard; Bluetooth and Ethernet modules are optional, and settings are saved automatically.

💡 Bottom line

The A24PA V1.3 is not a bigger controller — it is a different architecture. Putting ATS and MPPT on the same power stage removes the extra box, the extra wiring and most of the extra cost of a dual-source site.

If your loads cannot afford a bad week, that is usually a better investment than another 200 W of panel.

← Next: Application Dictates Your MPPT Choice Previous: SUNOPEN H20TB Boost MPPT Guide →